FSD60-VALR : UL Classified 1 1/2 hr. Class I, Airfoil Blade, Validator Ready


The FSD60-VALR Combination Fire/Smoke Damper is both UL555 and UL555S Classified. It is rated as a 1-1/2 hour fire damper and a Leakage Class I Smoke damper.

 

It features:

  • Validator ready, damper supplied with RSDC (controller).
  • True one-piece airfoil blades.
  • Rated to 4,000 fpm and 4" w.g.
  • UL approval for dual directional airflow.
  • Failsafe design, which enables the damper to automatically assume the desired position when fire or smoke (if smoke detector is present) interrupts operational power.
  • Controlled closure in not less than 3 seconds and no more than 15 seconds to prevent HVAC and duct damage.
  • Automatic remote reset after test, smoke detection or power failure conditions.
Galvanized steel construction.
Documents:
Product Data
Product Data/Submittal (PDF)
Installation Instructions
Basic Installation Sheet (PDF)
IBD2G, IBD2SSG, IBD20G, DIBD2G, DIBD2SSG, DIBD20G & IBDTG
Supplemental Installation Instructions
Cavity Shaft Wall Metal Stud Framing
Concete with steel decking
Extension of Damper Sleeves
Fire Resistant Ventilated Duct Assembly
Flanged Breakaway Connections
Optional Damper Sealant
Optional FireStop Material
S and Drivemate
SP100 and SP100FK Field Installation Instruction
TDF and TDC Field Add-On Connections
Transfer Openings and Duct Terminations
Trimming for Fire & Combination F/S Damper Sleeves Installation Supplement
Technical Information
Actuator Space Envelope
Combination Fire/Smoke and Smoke Dampers Air Performance Data
Controlled Closure
FM Approval
FSD Minimum Size for Actuator in the Airstream
Sleeve Flange Breakaway Connections
UL555-555S
Validator
Accessories
FAST and PFMA
DSDF - Flow Duct Smoke Detector
DSDF - Hochiki DH-98
DSDN - No-Flow Duct Smoke Detector
HS-100 Series Duct Smoke Detectors
Security Bars Option
SP-100
SPH2
Specifications
CSI 3-Part Guide Specification (RTF)
CAD Drawings
View CAD Drawing (PDF)
Download CAD Drawing (DWG)
View CAD Installation Drawing (PDF)
Download CAD Installation Drawing (DWG)
Duct Smoke Detector CAD Drawing
DuctMate CAD Drawing
Electric Fuse Link CAD Drawing
Electric Fuse Link/SP100 CAD Drawing
Metal Stud Framing CAD Drawing
Metal Stud Framing in U438 Drywall CAD Drawing
Picture Frame Mounting Angles CAD Drawing
Pneumatic Fuse Link CAD Drawing
S & Drivemate CAD Drawing
Sealant CAD Drawing
Transfer Openings CAD Drawing
TS150EZ CAD Drawing
View Duct Smoke Detector CAD drawing (PDF)
View DuctMate CAD Drawing (PDF)
View Electric Fuse Link CAD Drawing (PDF)
View Electric Fuse Link/SP100 CAD Drawing (PDF)
View Metal Stud Framing CAD Drawing (PDF)
View Metal Stud Framing in U438 Drywall CAD Drawing (PDF)
View Picture Frame Mounting Angles CAD Drawing (PDF)
View Pneumatic Fuse Link CAD Drawing (PDF)
View S & Drivemate CAD Drawing (PDF)
View Sealant CAD Drawing (PDF)
View Transfer Openings CAD Drawing (PDF)
View TS150EZ CAD Drawing (PDF)
Operation Options / Wiring Diagrams
Electric Fuse Link (EFL)
Electronic Fuse Link / SP100
Framing Details
Tunnel Corridor Framing Instruction
Actuators
331-2961 - Pneumatic Two Position Spring Return - Siemens
331-3060 - Pneumatic Two Position Spring Return - Siemens
331-4827 - Pneumatic Two Position Spring Return - Siemens
FSAF120-24- S
FSLF120-24-S
FSNF120, FSNF24 - 120 and 24 VAC Two Position Spring Return - Belimo
GGD221 - 120 VAC Two Position Spring Return - Siemens
H-2000, H-2024 - 120/24 VAC Two Position Spring Return - Honeywell
H2000 Replacement for MP2781
ML4202, ML8202 - 120/24 VAC Two Position Spring Return - Honeywell
MS4120F, MS8120F,S Fast-Acting Two Position Actuators - Honeywell
MS4209, MS8209 - 120/24 VAC Two Position Spring Return - Honeywell
 

Share This Page