Ruskin Louvers Teach a Lesson

Geometry students at Santa Fe Trail Jr. High School in Olathe, Kansas have discovered a new use for Ruskin louvers—providing real life applications to geometry problems. Ruskin, the worldwide leader in air and sound control, provided louvers of several different shapes to eighth graders at the school for use as a teaching aid in their geometry class.

Read the rest of entry »

Ruskin Co.'s avatar

NEW CSI 3-Part Format Specs for NEW UL Standard Life Safety Dampers - Updated

NEW CSI 3-Part Format Specs for NEW UL Standard Life Safety Dampers.

Read the rest of entry »

Ruskin Co.'s avatar

Ruskin Economizer

Ruskin is now in the Economizer business! Introducing Ruskin’s complete line of automated Economizer dampers for rooftop air handlers ranging from 3-25 tons for both horizontal and vertical applications.

Read the rest of entry »

Ruskin Co.'s avatar

UL Test Standard Changes: What Do They Mean to You? (Updated!)

ALL NEW UL555 (Fire Damper) and UL555S (Smoke Damper) Test Standards begin JULY 1, 2002! What do they mean to you?

Read the rest of entry »

Ruskin Co.'s avatar

Factory Mounted Smoke Detectors

Smoke control is a proven technology that saves lives.  Smoke or combination fire/smoke dampers and the devices that control them, such as smoke detectors, are important components of a smoke control system. It is important to understand that smoke dampers do not inherently detect the presence of smoke.  It is a corresponding smoke detector that normally causes the damper to close and thus "stop" smoke from leaking through the damper. UL555S, the UL Smoke Damper Test Standard, recognizes three different leakage classes.  Smoke or combination fire/smoke are tested and rated according to one of the following classes: Class 1 leakage is 4 cfm/sqft at 1” w.g. or less Class 2 leakage is a maximum of 10 cfm/sqft at 1” w.g. Class 3 leakage is a maximum of 40 cfm/sqft at 1” w.g. The volume of air leaking through a closed damper represents smoke "leaking" through the damper during a fire.  In life safety situations it makes good engineering sense to specify and install minimum Class 2 smoke or combination fi ...

Read the rest of entry »

Ruskin Co.'s avatar

Ruskin makes it a “Cinch” to install round life safety dampers.

Are you specifying, purchasing and installing the best fire or fire/smoke damper in round penetrations?

Read the rest of entry »

Ruskin Co.'s avatar

A Fire Damper Paradigm Shift

Did you know fire and combination fire/smoke dampers could be installed with RUSKIN FAST mounting angle on ONLY one side of the wall? YES, YOU HEARD IT CORRECTLY!!!  Ruskin - Made it Happen!!Traditional Ruskin fire and combination fire/smoke dampers may be installed in metal stud, wood stud and concrete wall applications with mounting angles installed on only one side of the wall.  The benefits of the FAST one-side angle paradigm shift are:UL tested and approved instructions$25-$50 installation savings per damperGreat for retrofit applications with limited accessMaximum size of 90"w x 49"h or 49"w x 90"hMetal stud, wood stud and concrete wall applicationsAbility to install prior to gypsum being installedThe new Ruskin FAST angle incorporates a flat angle design so the damper and mounting angle can be installed prior to installing the gypsum wallboard.  Wow, what labor savings for the installing contractor!!!!Ruskin, also provides the angle one-side option as an integral part of the damper.  This eliminates wa ...

Read the rest of entry »

Ruskin Co.'s avatar

Swartwout Online Catalog Now Available!

The Swartwout online product catalog is now online for viewing! You can find the latest Submittals, spec sheets, CSI specs, and CAD drawing for Swartwout models, with category browsing and full search capabilities!

Read the rest of entry »

Ruskin Co.'s avatar

Security Bars in Combo with Life Safety Dampers - Revised!

Ruskin 1 ½ hour rated combination fire/smoke, smoke and fire dampers are available with factory supplied and installed security bars in a common sleeve. The life safety damper maintains the UL classification. Ruskin eliminates all the ordering and field coordination of security bars and life safety dampers. One company, one source, one delivery!!!!Standard Security Bar Options:Bars and frame are cold rolled steel (CRS).Rockwell Hardness B80/90, AISI 1018, Cold Drawn, ASTM-A-108 CertifiedVertical bars are1/2" diameter round, 6" on center.Optional 3/4" & 1" diameter, 4" – 6" on centerHorizontal bars are 2" x 1/4" flat bar – 12" on centerGrille frame – 10 gage x 2" galvanized steelThe vertical bars pass through the horizontal bar(s). Bars are welded to the frame and at each intersection of the horizontal bar. Consult Ruskin if options are desired other than the standard options listed above. Consult our security bars spec sheet online for submittal and data information. In addition for information concerning pri ...

Read the rest of entry »

Ruskin Co.'s avatar

New UL Test Standards for Fire and Smoke Dampers

Underwriters Laboratories have developed more stringent test requirements for Fire and Smoke dampers, which become effective July 1, 2002.

Read the rest of entry »